Part Number Hot Search : 
DA0996 30KP84A G1H15 16ED10E LU1S025 B103P 78RB12T 09012
Product Description
Full Text Search
 

To Download MB4000RU Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  key features: ? 40w output power ? 4:1 input voltage range ? 1,500 vdc isolation ? single & dual outputs ? ef? ciency to 91% ? compact 1 x 2 inch case ? wide temp operation ? industry standard pin-out ? low cost MB4000RU compact, 1 x 2 inch 40w, 4:1 input range dc/dc con vert ers input parameter conditions min. typ. max. units input voltage range 24 vdc input 9.0 24.0 36.0 vdc 48 vdc input 18.0 48.0 75.0 input start voltage 24 vdc input 9.0 vdc 48 vdc input 18.0 under voltage shutdown 24 vdc input 8.3 vdc 48 vdc input 16.5 input filter lc filter start-up time see note 1 30 ms output parameter conditions min. typ. max. units output voltage accuracy ?.0 % output voltage balance dual outputs, balanced loads ?.0 % output trim range ?0 % line regulation v in = min to max ?.5 % load regulation, see note 2 single output ?.5 % dual output ?.0 cross regulation see note 3 ?.0 % ripple & noise (20 mhz), see note 4 3.3 & 5 v out models 100 mv p - p 12, 15 & 24 v out models 150 dual output models 150 transient recovery time, see note 5 25% load step change 250 ?ec transient response deviation ?.0 ?.0 % temperature coef cient ?.02 %/? over temperature protection shutdown temperature 110 ? output power protection 150 % output short circuit, see note 6 continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage 60 seconds 1,500 vdc isolation resistance 500 vdc 1,000 m? isolation capacitance 100 khz/1.0v 1,500 pf switching frequency see note 7 320 khz environmental parameter conditions min. typ max. units operating temperature range, ambient without heatsink mb40xxs-03ru -40 +25 +66 ? mb40xxs-05ru, mb4048s-12ru, -15ru +51 mb4024s-12ru, mb4024s-15ru +45 mb40xxs-24ru +57 mb40xxd-xxru +40 operating temperature range, ambient with heatsink mb40xxs-03ru -40 +25 +73 ? mb40xxs-05ru, mb4048s-12ru, -15ru +61 mb4024s-12ru, mb4024s-15ru +57 mb40xxs-24ru +66 mb40xxd-xxru +52 operating temperature range case +105 ? storage temperature range -50 +125 ? humidity rh, non-condensing 95 % physical case size, see note on page 4 2.0 x 1.0 x 0.40 inches (50.8 x 25.4 x 10.2 mm) case material aluminum alloy with non-conductive base (ul94-v0) weight 1.06 oz (30g) reliability speci? cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 328 khours absolute maximum ratings parameter conditions min. typ. max. units input voltage surge (1 sec) 24 vdc input -0.7 50.0 vdc 48 vdc input -0.7 100.0 lead temperature 1.5 mm from case for 10 sec 260 ? caution: exceeding absolute maximum ratings may damage the module. these are not continuous operating ratings. electrical speci? cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com series
model selection guide 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com notes: 1. start up time is measured at nominal input and with a constant resistive load. 2. load regulation is speci ed for a load change of minimum load to full load. 3. cross regulation is measured with the output being tested at 100% load. the second output is varied from 25% to 100% load. 4. when measuring output ripple, it is recommended that an external 1 ? capacitor and 10 ? capacitor be connected in parallel from the +v out to the -v out pins for single output units and from each output to common for dual output units. 5. transient recovery is measured to within a 1% error band for a load step change of 25%. 6. short circuit protection is provided by a ?iccup mode circuit. 7. the switching frequency for 24 vdc output models is 285 khz. 8. operation at no-load will not damage these units. however, they may not meet all speci cations if operated below the speci ed minimum load. 9. it is recommended that a fuse be used on the input of a power supply for protection. see the model selection table above for the correct rating. model number input output ef? ciency (%, typ) over voltage protection (vdc typ) capacitive load (f, max) fuse rating slow-blow (a) voltage (vdc) current (ma) voltage (vdc) current (ma, max) current (ma, min) nominal range full-load no-load mb4024s-03ru 24 9.0 - 36.0 1,240 90 3.3 8,000 0 89 3.9 21,000 8.0 mb4024s-05ru 24 9.0 - 36.0 1,850 90 5.0 8,000 0 90 6.2 13,600 8.0 mb4024s-12ru 24 9.0 - 36.0 1,870 95 12.0 3,330 0 89 15.0 2,400 8.0 mb4024s-15ru 24 9.0 - 36.0 1,870 105 15.0 2,670 0 89 18.0 1,500 8.0 mb4024s-24ru 24 9.0 - 36.0 1,835 115 24.0 1,670 0 91 30.0 600 8.0 mb4024d-12ru 24 9.0 - 36.0 1,890 65 ?2.0 ?,670 ?45 88 ?5.0 ?,200 8.0 mb4024d-15ru 24 9.0 - 36.0 1,890 65 ?5.0 ?,330 ?10 88 ?8.0 ?50 8.0 mb4048s-03ru 48 18.0 - 75.0 620 55 3.3 8,000 0 89 3.9 21,000 4.0 mb4048s-05ru 48 18.0 - 75.0 930 55 5.0 8,000 0 90 6.2 13,600 4.0 mb4048s-12ru 48 18.0 - 75.0 930 60 12.0 3,330 0 90 15.0 2,400 4.0 mb4048s-15ru 48 18.0 - 75.0 930 65 15.0 2,670 0 90 18.0 1,500 4.0 mb4048s-24ru 48 18.0 - 75.0 918 75 24.0 1,670 0 91 30.0 600 4.0 mb4048d-12ru 48 18.0 - 75.0 950 45 ?2.0 ?,670 ?45 88 ?5.0 ?,200 4.0 mb4048d-15ru 48 18.0 - 75.0 950 45 ?5.0 ?,330 ?10 88 ?8.0 ?50 4.0 on single output units, an external resister may be added to adjust the converter output. to adjust the output up, connect a 5%, 3w resistor between the minus output pin (5) and the vout trim pin (6). to adjust the output down, connect a 5%, 3w resistor between the plus output pin (4) and the vout trim pin (6). the trim table at right gives suggested resistor values for this adjustment. external trim remote on/off mb40xxs-03ru trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 72.61 32.55 19.20 12.52 8.51 5.84 3.94 2.51 1.39 0.50 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 60.84 27.40 16.25 10.68 7.34 5.11 3.51 2.32 1.39 0.65 k  mb40xxs-05ru trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 138.88 62.41 36.92 24.18 16.53 11.44 7.79 5.06 2.94 1.24 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 106.87 47.76 28.06 18.21 12.30 8.36 5.55 3.44 1.79 0.48 k  mb40xxs-12ru trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 413.55 184.55 108.22 70.05 47.15 31.88 20.98 12.80 6.44 1.35 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 351.00 157.50 93.00 60.75 41.40 28.50 19.29 12.37 7.00 2.70 k  mb40xxs-15ru trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 530.73 238.61 141.24 92.56 63.35 43.87 29.96 19.53 11.41 4.92 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 422.77 189.89 112.26 73.44 50.15 34.63 23.54 15.22 8.75 3.58 k  mb40xxs-24ru trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 333.39 148.80 87.26 56.50 38.04 25.73 16.94 10.35 5.22 1.12 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 243.70 108.50 63.43 40.90 27.38 18.37 11.93 7.10 3.34 0.34 k  applying a signal to pin 3 will turn the unit on/off . if the pin is left open, the unit operates. if grounded, the unit will shut off. the speci cations for the on/off function are: parameter min typ max units supply on 3.5 12.0 vdc supply off 0.0 1.2 vdc standby input current 2.5 ma control common referenced to negative input (pin 2) control input current (on) 0.5 ma control input current (off) -0.5 ma for heatsink option, add suf x ??to model number (i.e. mb4024s-15ru-h)
micropower direct 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com mb40xxs-03ru without heatsink mb40xxs-03ru with heatsink mb40xxs-05ru, mb4048s-12ru mb4048s-15ru without heatsink mb40xxs-05ru, mb4048s-12ru mb4048s-15ru with heatsink mb4024s-12ru, mb4024s-15ru without heatsink mb4024s-12ru, mb4024s-15ru with heatsink mb40xxd-12ru, mb40xxd-15ru without heatsink mb40xxd-12ru, mb40xxd-15ru with heatsink mb40xxs-24ru without heatsink mb40xxs-24ru with heatsink derating curves www.micropowerdirect.com
micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com notes: all dimensions are typical in inches (mm) tolerance x.xx = ?.02 (?.50) heatsink is black, anodized aluminum mechanical dimensions mechanical dimensions: with optional heatsink pin single output 1+vin 2-vin 3 remote on/off 4 +vout 5 -vout 6 trim pin dual output 1+vin 2-vin 3 remote on/off 4 +vout 5 common 6 -vout pin con nec tions for the heatsink option, add suf x ??to the model number (i.e. mb4048d-12ru-h) parameter standard radiated emissions en 55022 class a conducted emissions en 55022 class a esd en 61000-4-2 criteria b; ? kv air, ? kv contact rs en 61000-4-3 criteria a; 10v/m eft, see notes en 61000-4-4 criteria a; ? kv surge, see notes en 61000-4-5 criteria b; ? kv cs en 61000-4-6 criteria a; 10 v/m all units should meet en 55022 (ce/re) class a/b with the simple external circuit shown; using the component values given in the table. to meet the requirements of en 61000-4-4 and en 61000-4-5, the value of c 1 should be changed to 330 f/200v. contact the factory for more information. standard model c 1 c 2 l 1 c 3 c 4 en55022 class a mb4024x-xxru 4.7 ?/50v 1812 mlcc --- --- 1,000 pf/2kv 1808 mlcc 1,000 pf/2kv 1808 mlcc mb4048x-xxru 2.2 ?/100v 1812 mlcc --- --- 1,000 pf/2kv 1808 mlcc 1,000 pf/2kv 1808 mlcc en55022 class b mb40xxx-xxru 3.3 ?/100v 1210/x7s 3.3 ?/100v 1812 mlcc 700 ? 680 pf/2kv 1808 x7r 680 pf/2kv 1808 x7r mb40xxx-24ru 4.7 ?/100v 1210/x7s 3.3 ?/100v 1812 mlcc 700 ? 1,000 pf/2kv 1808 x7r 1,000 pf/2kv 1808 x7r emc speci? cations


▲Up To Search▲   

 
Price & Availability of MB4000RU

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X